Skip to main content

How to Keep Your Westinghouse Portable Generator Running and Stored Safely

What Westinghouse Portable Generators Are Built For

Westinghouse portable generators are designed to run on gasoline or dual fuel (gasoline and propane), with power outputs ranging from around 3,500 watts to 12,500 watts depending on the model. They're built for backup power during outages, job site work, and outdoor events. Unlike larger standby units, these sit outside your home and connect to appliances through extension cords or a manual transfer switch.

The brand has been making generators since the 1980s and focuses on affordability and mid-range reliability. Most Westinghouse portables use a single-cylinder or twin-cylinder engine and come with wheels and a handle for moving between locations. Understanding your specific model's fuel type, wattage rating, and runtime will shape how you store it and what maintenance it needs.

Key Takeaways

  • Westinghouse portable generators must be stored in a dry location with fuel drained or stabilized, because gasoline breaks down and clogs the carburetor during months of sitting.
  • Check your owner's manual for the exact oil type and capacity before your first run, because using the wrong oil voids the warranty and damages the engine.
  • Run the generator under load (connected to actual appliances) for at least 30 minutes every three months during storage to keep the engine and carburetor clear.
  • Propane models last longer in storage than gasoline models because propane does not degrade, but both need a dry, well-ventilated space away from living areas.
  • Never run a generator indoors, in a garage, or near windows and doors, because the exhaust contains carbon monoxide, which is colorless and deadly.

Draining and Stabilizing Fuel for Long Storage

Gasoline left in a Westinghouse generator for more than 30 days will begin to break down and leave varnish deposits in the carburetor and fuel lines. This is the most common reason a generator won't start after sitting through winter or a quiet season. You have two options: drain the tank completely, or add fuel stabilizer and run the engine to circulate it through the system.

To drain the tank, locate the fuel valve (usually a small lever or knob on the bottom of the tank) and turn it to the "Off" position. Unscrew the drain plug at the base of the carburetor bowl and let the fuel flow into a metal container. Catch all the fuel—gasoline is flammable and must be disposed of at a hazardous waste facility, not poured down a drain. Once the tank is empty, turn the fuel valve back to "On" and run the engine until it stops, which clears fuel from the carburetor.

If you prefer to keep fuel in the tank, add a fuel stabilizer like Sta-Bil or PRI-G according to the bottle's instructions (usually one ounce per five gallons). Run the engine for 10 to 15 minutes so the stabilizer circulates through the fuel system. This method works well for propane models, which don't need stabilizer because propane doesn't degrade.

Oil Changes and Engine Maintenance Before Storage

Check your Westinghouse manual for the correct oil type—most small generators use SAE 10W-30 or SAE 15W-40, but some require straight 30-weight oil. Using the wrong viscosity can cause starting problems and engine wear. Drain the old oil while the engine is still warm (but not hot) by locating the drain plug underneath the engine and letting the oil flow into a pan. Dispose of used oil at an auto parts store or hazardous waste facility.

Refill with the correct amount of fresh oil—overfilling is as damaging as underfilling because it can foul the spark plug and cause smoking. Most Westinghouse portables hold between 0.6 and 1.1 quarts depending on the engine size. Check the dipstick or sight glass to confirm the level is at the "Full" mark. If you're storing the generator for more than three months, change the oil before storage so old oil doesn't sit in the engine and corrode internal parts.

While you have the engine cover off, inspect the spark plug for heavy carbon buildup or corrosion. A fouled spark plug is often why a stored generator won't start. Clean it with a wire brush or replace it if the gap is too wide or the electrode is damaged. A new spark plug costs a few dollars and prevents frustration when you need the generator.

Choosing the Right Storage Location

Store your Westinghouse generator in a dry, well-ventilated space where it won't be exposed to rain, snow, or high humidity. A shed, garage corner, or covered outdoor area works well as long as moisture can't pool around it. Humidity and condensation inside the fuel tank and carburetor will cause rust and corrosion, making the engine harder to start and potentially damaging fuel lines.

Keep the generator away from your home's living spaces, windows, and doors. Even though you won't run it indoors, fuel fumes and the smell of old gasoline can seep into your home over time. If you store it in a garage, position it as far from the door to your house as possible and ensure the garage door can open fully for ventilation when you do run it.

Protect the generator from dust and pests by covering it with a tarp or generator cover, but leave enough air circulation so moisture doesn't trap underneath. Rodents are attracted to fuel and may chew through hoses or wiring, so store it away from food sources and consider placing it on a shelf or pallet rather than directly on the ground.

Running Your Generator Every Three Months

Even during storage, run your Westinghouse generator under load for at least 30 minutes every three months. This keeps the engine seals lubricated, prevents fuel from gumming up the carburetor, and confirms the unit will start when you need it. "Under load" means the generator is actually powering something—a work light, space heater, or extension cord with appliances plugged in—not just running idle.

Before starting, check the oil level, inspect the spark plug, and make sure the fuel valve is in the "On" position. Prime the engine by moving the choke to the "Start" or "Cold" position if your model has one. Pull the recoil cord firmly and steadily until the engine catches. Once it's running, let it warm up for a minute, then switch the choke to "Run" and connect a load to the outlet.

If the generator doesn't start after a few pulls, don't force it. Check that the fuel valve is open, the spark plug is clean, and there's fresh fuel in the tank. If it still won't start, the carburetor may be clogged and need professional cleaning—this is worth doing before the season when you'll actually need the generator.

Propane Versus Gasoline: Storage Differences

Westinghouse dual-fuel models can run on either gasoline or propane, and each fuel has different storage advantages. Propane doesn't degrade over time, so a propane-only generator or one running on propane can sit for years without fuel maintenance. The downside is that propane bottles take up space and must be stored outside in a well-ventilated area, away from heat sources and direct sunlight.

Gasoline models are simpler to refuel (you can use any gas station) but require the fuel management steps described above—draining or stabilizing before long storage. If you own a dual-fuel model and plan to store it for several months, consider running it on propane instead of gasoline. Switch to the propane fuel valve, let the engine run until it stops (clearing gasoline from the carburetor), then store it with an empty gas tank and a full propane bottle connected.

Propane bottles themselves need to be checked for leaks and corrosion. Inspect the valve and connection point for rust or damage before each use. If you smell rotten eggs (the odor added to propane for safety), turn off the valve immediately and move the bottle outside. Do not use the generator until the leak is repaired by a professional.

Troubleshooting a Generator That Won't Start After Storage

If your Westinghouse won't start after sitting for weeks or months, the most likely culprit is a clogged carburetor from old fuel. The fix depends on how long it's been sitting and whether you drained the tank. If you used fuel stabilizer and the engine still won't start, try running the choke through a full cycle: set it to "Start," pull the cord five times without releasing the choke, then move the choke to "Run" and pull again. Sometimes the stabilizer needs a few pulls to circulate.

If that doesn't work, remove the spark plug and inspect it for heavy black carbon or corrosion. Clean it with a wire brush or replace it. Check that the fuel valve is open and there's fuel in the tank. If the engine still won't turn over, the carburetor likely needs to be removed and cleaned by someone with small-engine experience—this is a job for a small-engine repair shop, not a DIY fix unless you're comfortable taking apart the engine.

To avoid this problem entirely, drain the fuel tank before storing for more than a month, or use fuel stabilizer and run the engine monthly. The 15 minutes of preventive maintenance is far easier than troubleshooting a dead generator when you need it most.

Frequently Asked Questions

Can I store a Westinghouse generator with fuel in the tank?

Yes, if you add fuel stabilizer and run the engine to circulate it through the system. Without stabilizer, gasoline will break down and clog the carburetor within 30 days. Propane models can be stored indefinitely with fuel because propane doesn't degrade.

What happens if I run a generator indoors?

The exhaust contains carbon monoxide, a colorless, odorless gas that causes poisoning and death within minutes. Always run the generator outside, at least 20 feet away from windows, doors, and vents. Never run it in a garage, basement, or shed with the door closed.

How often should I change the oil in a portable generator?

Change the oil every 50 to 100 hours of runtime, or at least once a year before storage season. Check your owner's manual for the exact interval for your model. If you store the generator for more than three months, change the oil before putting it away so old oil doesn't corrode the engine.

Why won't my generator start after sitting all winter?

Old fuel left in the tank and carburetor is the most common cause. Gasoline breaks down and leaves varnish that clogs the fuel system. If you drained the tank before storage, check the spark plug for fouling and make sure the fuel valve is open. If the engine still won't start, the carburetor may need professional cleaning.

Do I need to run my generator if I'm not using it?

Yes, run it under load for at least 30 minutes every three months during storage. This keeps the engine seals lubricated, prevents fuel from gumming up the carburetor, and confirms the unit will start when you need it. Skipping this step is why many stored generators fail to start.